Zinc Ribbon Anodes - Specification Chart

AC Mitigation | Cathodic Protection | Above Ground Storage Tanks
Grounding Rods | Grounding Mats
Technical Practices Document 1- Connection Practices
Technical Practices Document 2- Connection Practices - Crimps

Technical Practices Document - No. 2
Connection Practices - Crimps

Plattline I is an alloyed zinc product and generally used in seawater or brackish water systems. It meets the chemical requirements of MIL-A-18001K and ASTM B418-95a Type 1.

Plattline II is a high purity product and generally used in underground and frsh water systems. It meets the chemical requirements of ASTM B418-95a Type II.


CONNECTION PROCEDURE:
1. Remove 3" of zinc from iron core of anode ribbon.
2. Strip 3 1/2" of insulation from insulated copper cable without breaking copper strands.
3. Insert copper compression connector into jaws of installation tool.
4. Slip connector over both Plattline steel core and copper cable.
5. Crimp using recommended procedure with installation tool.
6. Wrap entire completed connection, including 1" of Plattline (each end) with insulated splice kit or with two half-lapped layers of rubber tape and two half-lapped layers of plastic tape.

<Previous Page

 

Top of Page


Manufacturers of zinc anodes, zinc ribbon anodes, thermal spray metalizing, corrosion control, ac mitigation, grounding systems, deep drawn stampings, zinc wire, eyelets, cathodic protection, and more.

The Platt Brothers & Company
800-752-8276
2670 So. Main St., Box 1030 E, Waterbury, Connecticut ( CT ) 06721
Tel: 203-753-4194 • Fax: 203-753-9709
General Information: info@plattbros.com

HomeRibbon AnodesZinc WireReroll & Strip
Zinc ShotEyelet ProductionEngineering CornerContact Us
HistoryRequest for QuoteSite Map

Web Design by Vision Marketing